What are the conventional sizes of access panel?

Published by Vairtech 2024-11-18

There is no special regulation on the size of the access panel, which can be handled flexibly according to the actual situation to facilitate maintenance.

  • If it is the access port of a specific equipment, the equipment needs to enter and exit from this port, and the access port should be 200mm wider than each side of the equipment.

  • Need to pass the human access port using 600mmx600mm, a little wider than the average person's shoulder on the line.
  • Do not need to pass the human access port, 400mm*400mm is enough, some very shallow easy to observe the access port, even do 300mm*300mm size is also possible.

  • The ceiling at the end of the air conditioner is generally lowered between 250mm and 300mm, and 300mm*500m is suitable for the access port.
  • The ceiling height of different air conditioners is also different. The minimum is about 200mm, and the maximum may reach 600mm.

For the ceiling hanging height is relatively large, the access port should be able to pass the size of people.